Note
Action
xx1200001070
Make sure the o-ring is present.
3
xx1200001066
Disconnect the motor cables.
4
xx1300000656
Remove the cable gland cover by perform-
ing the following steps:
1
Open the inner screw a little (the one
the arrow is pointing at). No need to
remove this screw from the motor.
2
Remove the outer screw.
3
Slide the cable gland cover away
from the inner screw. Make sure the
gasket is not damaged.
Tip
Make a note in which direction the cable
exit hole is facing, if the motor will be re-
moved too. The motor shall be refitted in
the same position.
5
Use caution and pull out the motor cables.
6
Continues on next page