Note
Action
Screws: M10x30 Stainless Steel
(3HAC060786-020)
Fit two of the attachment screws and
washers.
11
Washers: 13x17x2 Stainless Steel
(3HAC060866-003)
Remove the guide pins and replace with
the remaining attachment screws.
12
Bits extender: 3HAC12342-1
Secure the motor with its attachment
screws and washers.
13
Tightening torque: 50 Nm.
Use a bits extender in order to reach the
screws.
Screw dimension: M10x30 Stainless Steel
(3HAC060786-020) (4 pcs)
Washers: 13x17x2 Stainless Steel
(3HAC060866-003) (4 pcs)
xx1200001117
See
Performing a leak-down test on
Perform a leak-down test.
14
Connecting the motor cables
Note
Action
xx1300000738
Push the motor cables through the cable
gland opening.
1
Continues on next page
Product manual - IRB 6790
443
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
4 Repair
4.7.2 Replacing the axis-2 motor
Continued