Note
Action
xx1300001113
Pull out the carrier from its position.
6
xx1300000666
Pull out the axis-6 motor cables by holding
the cables with one hand at the motor and
the other at the carrier.
7
Removing the axis-6 motor
Note
Action
24 VDC power supply
To release the brakes, connect the 24 VDC
power supply.
1
Connect to R2.MP6-connector:
•
+ = pin 2
•
- = pin 5
xx1200001090
Unscrew the motor attachment screws.
2
Continues on next page
492
Product manual - IRB 6790
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
4 Repair
4.7.6 Replacing the axis-6 motor
Continued