Removing the axis-6 gearbox
Use these procedures to remove the axis-6 gearbox.
Preparations before removing the axis-6 gearbox
Note
Action
Decide which calibration routine to use,
and take actions accordingly prior to begin-
ning the repair procedure.
1
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
to the robot, before entering the safe-
guarded space.
2
See
Draining the axis-6 gearbox on
Drain the gearbox.
3
Remove all equipment fitted on the turning
disc.
4
Jog the robot to:
•
Axis 1 = No significance (as long as
the robot is secured to the founda-
tion).
•
Axis 2 = +25°
•
Axis 3 = +20°
•
Axis 4 = 0°
•
Axis 5 = -55°
•
Axis 6 = -10°
5
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
to the robot, before entering the safe-
guarded space.
6
xx1300000825
Remove the synchronization plate axis-6.
7
Continues on next page
604
Product manual - IRB 6790
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
4 Repair
4.8.4 Replacing the axis-6 gearbox
Continued
Summary of Contents for IRB 6790
Page 1: ...ROBOTICS Product manual IRB 6790 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 164: ...This page is intentionally left blank ...
Page 612: ...This page is intentionally left blank ...
Page 638: ...This page is intentionally left blank ...
Page 644: ...This page is intentionally left blank ...
Page 658: ...This page is intentionally left blank ...
Page 660: ...This page is intentionally left blank ...
Page 667: ......