Securing the robot to the base plate/foundation
Use this procedure to secure robot to base plate after fitting plate to the foundation.
Note
Action
800
B
B
B-B
(A)
(B)
(A)
xx1500000250
A Cylindrical guide pin (2 pcs)
B M5 x 40. Tightening torque 6
Nm. (x2)
Fit two guide pins to the guide pin holes in the
base plate.
Note
All screws and pins are delivered in a plastic
bag together with the base plate.
1
See
Lifting the robot with roundslings
.
Lift the robot.
2
Move robot close to its installation location.
3
Make sure the robot base is correctly
fitted onto the guide sleeves!
Guide the robot gently using two M24 screws
while lowering it into its mounting position.
4
Specified in
Note
Lightly lubricate screws before as-
sembly.
Fit the bolts and washers in the base attachment
holes.
5
Tighten bolts in a crosswise pattern to ensure
that the base is not distorted.
6
Product manual - IRB 6790
67
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
2 Installation and commissioning
2.4.5 Orienting and securing the robot
Continued
Summary of Contents for IRB 6790
Page 1: ...ROBOTICS Product manual IRB 6790 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 164: ...This page is intentionally left blank ...
Page 612: ...This page is intentionally left blank ...
Page 638: ...This page is intentionally left blank ...
Page 644: ...This page is intentionally left blank ...
Page 658: ...This page is intentionally left blank ...
Page 660: ...This page is intentionally left blank ...
Page 667: ......