Over pressure unit
Pressurized system
xx1700001181
Air inlet
A
Outlet air to flow sensor
B
Pressure relief valve
C
Display
D
The system is equipped with an over pressure unit and a flow sensor.
Over pressure unit
The over pressure unit let the air out if pressure exceeds 0.4 bar.
Flow sensor
The flow sensor controls the leakage in the system and have a small display which
shows the leakage value.
The balancing device is not monitored by the flow sensor.
The flow sensor supervision is active when the system is set to Motors On and
Auto.
Air leakage
There is a constant, normal, leakage in the system. The leakage value is individual
for each system and is set by ABB when manufactured.
If the leakage exceeds a predefined value, the system alerts with a signal to the
I/O system. If the system alerts for too high leakage, detect the leakage and seal
it.
The I/O system is alerted when the leakage value is described as x + 1 l/min = alert
value (where x - normal leakage for the system). Reset level is set to x + 0.5 l/min.
Continues on next page
Product manual - IRB 6790
73
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
2 Installation and commissioning
2.4.6 Installation requirements for Foundry Prime robots
Continued
Summary of Contents for IRB 6790
Page 1: ...ROBOTICS Product manual IRB 6790 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 164: ...This page is intentionally left blank ...
Page 612: ...This page is intentionally left blank ...
Page 638: ...This page is intentionally left blank ...
Page 644: ...This page is intentionally left blank ...
Page 658: ...This page is intentionally left blank ...
Page 660: ...This page is intentionally left blank ...
Page 667: ......