Note
Action
Tightening torque: 45 Nm
Fit the Distance tool on the back of the
balancing device using the four screws.
DANGER
Use caution when tightening the screws.
The threads in the cover can be damaged
if more tightening torque than 45 Nm is
used, risking that the Distance tool is not
properly fitted.
5
Attachment screws: M10x30 Stainless Steel
(3HAC060786-020) (4 pcs)
A
xx0800000480
A Distance tool: 3HAC030662-001
Turn the power on temporary.
6
This is done to compress the balancing
device springs, making it possible to re-
move the front shaft of the balancing
device.
Jog axis-2 to the calibration position.
The balancing device is now unloaded.
7
Let the Distance tool stay fitted during the
continued procedure.
8
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
to the robot, before entering the robot
working area.
9
Attaching lifting accessory to the balancing device
Note
Action
CAUTION
The weight of the balancing device (exclud-
ing cradle) is 140 kg
All lifting accessories used must be sized
accordingly.
1
Continues on next page
Product manual - IRB 6790
549
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
4 Repair
4.8.2 Replacing the axis-2 gearbox
Continued
Summary of Contents for IRB 6790
Page 1: ...ROBOTICS Product manual IRB 6790 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 164: ...This page is intentionally left blank ...
Page 612: ...This page is intentionally left blank ...
Page 638: ...This page is intentionally left blank ...
Page 644: ...This page is intentionally left blank ...
Page 658: ...This page is intentionally left blank ...
Page 660: ...This page is intentionally left blank ...
Page 667: ......