2.4.3 Securing the base plate
Base plate, dimensions
A
A
B
B
C
D
G
H
E
F
2x R525
598,31
560,85
487,01
243,5
0
73,84
111,30
1020
857,3
73,84
132,64
317,3
502,04
560,85
634,68
0
2x 50x45º
231,5
2x 450
950
(Ø 800)
12x M24
Ø1 A
455
C
A
4x48
13
(2)
1,6
3x45º
0.3
Ø 45P7
A-A
Ø1.5
(4x)
6,3
(48)
(2)
1,6
3x45º
B-B
(2)
13
3x R1
3x4
3x 90º
C-C
45
K
7
+0,5
0
47
0,25 c
(2x R22,5)
1,6
D
(2)
c
52,5º
Common Zone
E, F, G, H
xx1000001053
Common tolerance zone (accuracy all over the base plate from one contact
surface to the other)
E, F, G, H
Continues on next page
Product manual - IRB 6790
57
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
2 Installation and commissioning
2.4.3 Securing the base plate
Summary of Contents for IRB 6790
Page 1: ...ROBOTICS Product manual IRB 6790 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 164: ...This page is intentionally left blank ...
Page 612: ...This page is intentionally left blank ...
Page 638: ...This page is intentionally left blank ...
Page 644: ...This page is intentionally left blank ...
Page 658: ...This page is intentionally left blank ...
Page 660: ...This page is intentionally left blank ...
Page 667: ......