Air quality for pressurizing the robot
The air must be dry and clean, such as instrument air. The following table describes
the air specifications.
WARNING
If the pressurized air contains oil, it could result in a brake failure in the motors
and cause the robot arms to fall down, leading to personal injury or physical
damage.
Value
Parameter
<+2°C at 6 bar
Dew point
<5 microns
Solid particle size
<1 ppm (1 mg/m
3
)
Oil content
>200 L/min
Air flow
0.2-0.3 bar
Air pressure
Setup the flow sensor
Note
Action
Event log 37110 appears in cases
where the signal is not set.
Configure the signal at setup via the I/O system.
Set Leak Detection On to TRUE.
xx1700001401
1
If required, setup an output signal (warning lamp
etc.)
2
Set the flow sensor
The procedure is needed after replacement of, for example, cable harness. All
values are set in factory at delivery.
A
B
B
C
xx1900000621
Display
A
Continues on next page
74
Product manual - IRB 6790
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
2 Installation and commissioning
2.4.6 Installation requirements for Foundry Prime robots
Continued
Summary of Contents for IRB 6790
Page 1: ...ROBOTICS Product manual IRB 6790 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 164: ...This page is intentionally left blank ...
Page 612: ...This page is intentionally left blank ...
Page 638: ...This page is intentionally left blank ...
Page 644: ...This page is intentionally left blank ...
Page 658: ...This page is intentionally left blank ...
Page 660: ...This page is intentionally left blank ...
Page 667: ......