Note/Illustration
Action
Connect the adapter cable to the digital
base.
•
K5.1.X5 - A2.X4/K4.X7
Note
If the Ethernet extension switch is
installed, connect and disconnect
the connector K5.1.X5 to/from
K4.X7.
If the Ethernet extension switch is
not installed, connect and discon-
nect the connector K5.1.X5 to/from
A2.X4.
•
K5.1.X4 - K2.X3
•
The harness connected to I/O unit
by customer
4
Installing scalable I/O external devices
For more information about installing, configuring, and using the scalable I/O units,
see
Application manual - Scalable I/O
.
Note/Illustration
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
1
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
2
Prepare the scalable I/O units for external
mounting as described in
Application
manual - Scalable I/O
.
3
.
Open the door.
4
Connect the external base device to the
internal base device (X3) or the Ethernet
switch, using an Ethernet cable.
5
Each base device requires its own power
supply.
Connect an external power supply to the
external base units, connector X4.
6
.
Close the door.
7
Perform the function tests to verify that
the safety features work properly, see
8
Product manual - OmniCore C90XT
117
3HAC073706-001 Revision: E
© Copyright 2020-2021 ABB. All rights reserved.
3 Installation and commissioning
3.7.2 Installing the scalable I/O devices
Continued
Summary of Contents for OmniCore C90XT
Page 1: ...ROBOTICS Product manual OmniCore C90XT ...
Page 36: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 360: ...This page is intentionally left blank ...
Page 420: ...This page is intentionally left blank ...
Page 428: ...This page is intentionally left blank ...
Page 452: ...This page is intentionally left blank ...
Page 456: ......
Page 457: ......