4 Maintenance
4.1 Maintenance schedule, OmniCore
General
The controller must be maintained at regular intervals to ensure its function. The
activities and intervals are described in this section.
Activities and intervals
Detailed in section:
Interval
Maintenance
activity
Equipment
Inspecting the OmniCore C90XT
controller on page 162
12 months
i
Inspection
Complete controller
Cleaning air filter on page 163
Cleaning
Air filter
Replacement of air filter on page 168
24 months *
Replacement
Air filter
Inspecting the OmniCore C90XT
controller on page 162
6 months
Inspection
System fans
Cleaning of the controller cabinet
on page 165
Cleaning
Control cabinet
Cleaning the FlexPendant on
page 166
When needed
Cleaning
FlexPendant
Function test of emergency stop on
page 171
12 months
Function test
Emergency stop
(FlexPendant)
Function test of manual, auto, and
manual full speed mode with Flex-
Pendant on page 172
12 months
Function test
Manual, auto and
manual full speed
mode with FlexPend-
ant
Function test of three-position en-
abling device on page 173
12 months
Function test
Enable device
Function test of contactors A1.Q1
and A1.Q2 inside the power unit on
page 174
12 months
Function test
Contactors A1.Q1
and A1.Q2
Function test of auto stop on
page 175
12 months
Function test
Auto stop (tested if
used)
Function test of external emergency
stop on page 176
12 months
Function test
External emergency
stop (tested if used)
Function test of ESTOP_STATUS
output on page 177
12 months
Function test
ESTOP_STATUS
output (tested if
used)
Function test of reduced speed
control on page 178
.
During commis-
sioning
Function test
Reduced speed
control
i
The interval depends on the working environment of the equipment: a cleaner environment may
extend the maintenance interval and vice versa.
Function test after replacement of component
After replacing a component in the controller, the function tests should be
performed. See
Product manual - OmniCore C90XT
161
3HAC073706-001 Revision: E
© Copyright 2020-2021 ABB. All rights reserved.
4 Maintenance
4.1 Maintenance schedule, OmniCore
Summary of Contents for OmniCore C90XT
Page 1: ...ROBOTICS Product manual OmniCore C90XT ...
Page 36: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 360: ...This page is intentionally left blank ...
Page 420: ...This page is intentionally left blank ...
Page 428: ...This page is intentionally left blank ...
Page 452: ...This page is intentionally left blank ...
Page 456: ......
Page 457: ......