Refitting the connected services gateway
Note/Illustration
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
1
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
2
xx1900001890
Hook up the connected services gateway
to the bracket and push carefully into
position.
Note
During the installation, the gap between
the lower surface of the Connected Ser-
vices Gateway and the upper surface of
the main computer should be zero.
3
xx1800000495
TOP VIEW
Continues on next page
Product manual - OmniCore C90XT
241
3HAC073706-001 Revision: E
© Copyright 2020-2021 ABB. All rights reserved.
5 Repair
5.2.8 Replacing the main computer
Continued