Note/Illustration
Action
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
2
Insert the manipulator signal connector
into the cover from inner side of the
cabinet.
3
Screws: Torx pan head screw M4x8 (4 pcs)
Secure it with the attachment screws.
4
xx1900001915
xx1900001914
Reconnect and secure:
•
K6.X4, K6.X5 - SMB.
5
Concluding procedure
Note/Illustration
Action
.
Close the door.
1
Perform the function tests to verify that
the safety features work properly, see
2
Product manual - OmniCore C90XT
297
3HAC073706-001 Revision: E
© Copyright 2020-2021 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the manipulator signal connector (SMB)