7.2.3 System update failure
Description
In certain scenarios, such as removing or adding certain optional features or major
upgrades of installed software products versions, the previous backup may be
incompatible with the newly re-configured system. Automatically reloading backup
can therefore fail, resulting in system failure state.
For more information about system update, see
Operating manual - Integrator's
guide OmniCore
.
Recommended working procedure
If there is a system update failure, the RobotWare system must be reset, which
will bring the system state to the default empty state for the current configuration.
See
Operating manual - Integrator's guide OmniCore
for detailed information
regarding system reset.
After reset, it is possible to:
A Go forward with the new configuration by re-implementing your programs
and configuration, or selectively reloading contents of the previous system
backup
B Rollback the changes in the system configuration, that is, make a new system
update and load the previous backup, and then manually update as needed
C Perform a complete re-installation of the RobotWare System using RobotWare
Installation Utilities and then reloading the previous backup.
See
Operating manual - Integrator's guide OmniCore
.
370
Product manual - OmniCore C90XT
3HAC073706-001 Revision: E
© Copyright 2020-2021 ABB. All rights reserved.
7 Troubleshooting
7.2.3 System update failure
Summary of Contents for OmniCore C90XT
Page 1: ...ROBOTICS Product manual OmniCore C90XT ...
Page 36: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 360: ...This page is intentionally left blank ...
Page 420: ...This page is intentionally left blank ...
Page 428: ...This page is intentionally left blank ...
Page 452: ...This page is intentionally left blank ...
Page 456: ......
Page 457: ......