3.6 I/O system
3.6.1 Available fieldbuses
General
The controller can be fitted with a number of different fieldbus adapters, fieldbus
boards, and software based fieldbuses. The software based fieldbuses do not
require any hardware.
Fieldbus connections
There is one slot available for installing a fieldbus board (PCIe) on the main
computer, with process connectors on the front panel, and one slot for installing
a fieldbus adapter (slave).
The software based fieldbuses are connected directly to one of the Ethernet ports.
D
C
B
A
xx1700000748
Fieldbus adapter (slave)
A
Slot for fieldbus adapters
B
Slot for fieldbus, PCI express card
C
Fieldbus board (master)
D
Available board
The following master board is available.
Type designation
Article number
Description
DSQC1006
3HAC043383-001
DeviceNet Board
Available software based fieldbuses
The following software based fieldbuses are available as RobotWare options.
•
EtherNet/IP
•
PROFINET
Continues on next page
108
Product manual - OmniCore C90XT
3HAC073706-001 Revision: E
© Copyright 2020-2021 ABB. All rights reserved.
3 Installation and commissioning
3.6.1 Available fieldbuses
Summary of Contents for OmniCore C90XT
Page 1: ...ROBOTICS Product manual OmniCore C90XT ...
Page 36: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 360: ...This page is intentionally left blank ...
Page 420: ...This page is intentionally left blank ...
Page 428: ...This page is intentionally left blank ...
Page 452: ...This page is intentionally left blank ...
Page 456: ......
Page 457: ......