1.2.1 Model 10DX3111E (continued)
10DX3111
E
_
_
_
_
_
_
_
_
_
_
_
_
_
_
Electrode Material
316 Stn. Steel
B
HASTELLOY
®
B
C
HASTELLOY
®
C
D
Titanium
E
Tantalum
F
Platinum / Iridium
H
Zirconium
L
Certification
Standard (None)
A
FM Approved-Nonincendive for Cl
I
, Div 2, Gp A,B,C & D; Electrodes Intrinsically Safe
for CI
I
, Div 1, Gp A,B,C & D; Outdoor Hazardous Locations, NEMA 4X. Dust-
Ignitionproof Cl
II,
Div1, Gp E,F & G: Suitable for Cl III, Div 1, Accidental
Submergence, 30ft H
2
O/48h (9m H
2
O/48h)
K
FM Approved-Explosionproof for Cl
I
, Div 1, Gp B,C & D; Dust-Ignitionproof Cl
II
,
Div 1, Gp E,F & G; Suitable for Cl
III
, Div 1; Electrodes Intrinsically Safe for CI
I
, Div
1, Gp A,B,C & D; Outdoor Hazardous Locations, NEMA 4X
L
Enclosure Classification
IEC 529 IP 65, NEMA 4X
1
Accidental Submergence: IEC 529, IP 67, NEMA-4X. 33ft H
2
O/48h (10m H
2
O/48h)
2
Accidental Submergence: IEC 529, IP 67, NEMA-4X. 33ft H
2
O/48h (10m H
2
O/48h)
Tropical-High Moisture Protection, Signal Cable Permanently Installed.
4
Continuous Submergence: IEC 529, IP 68, NEMA-4X. 33ft H
2
O/48h (10m H
2
O/48h)
Continuous Duty. Signal Cable Permanently Installed.
5
Accidental Submergence: IEC 529, IP 67, NEMA-4X. 33ft H
2
O/48h (10m H
2
O/48h)
Tropical-Improved Moisture Protection, Signal Cable Permanently Installed.
9
Liquid Temperature Range
Teflon, Rotomolded Tefzel, < 266
o
F (130
o
C)
1
Teflon, Extended Temperature, < 356
o
F (180
o
C)
2
Hard Rubber / Soft Rubber, < 176
o
F (80
o
C)
3
Neoprene / Polyurethane < 190
o
F (88
o
C)
4
Line Excitation Frequency
50 Hz / 6-1/4 Hz
1
50 Hz / 12-1/2 Hz
2
60 Hz / 7-1/2 Hz
3
60 Hz / 15 Hz
4
Customer Information Language
English w/ riveted SST tag
2
English w/ self-adhesive tag
8
Converter Type
50XM1000
1
none
X
Series 10DX3000 Magnetic Flowmeter Instruction Manual
1-5