Setup and function
Pos: 21 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Aufbau und Funkti on/T emperaturregler /Ver wendung 1094....1097, 1098 @ 26\mod_1342766379475_15.docx @ 224403 @ @ 1
The temperature controller is used to control the temperature in closed rooms.
Pos: 22 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Überschriften (--> Für all e D okumente <--)/2. Ebene/A - F /Funkti ons- und Ausstattungsmer kmal e @ 23\mod_1336557630140_15.docx @ 209136 @ 2 @ 1
6.1
Features of function and equipment
Pos: 23 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Aufbau und Funkti on/T emperaturregler /Funkti onen 1094....1097 @ 26\mod_1342708498968_15.docx @ 224389 @ @ 1
Article no.
Features / Function
1094 …
•
Opens when the set temperature is reached.
•
With separate connection for time-controlled reduction of nighttime temperature (4K).
•
Servo valves of "closed when de-energized“ design are required for the controller.
1095 …
•
Opens when the set temperature is reached.
•
With normally open contact (not applicable for 1095 UF)
•
With separate connection for time-controlled reduction of nighttime temperature (4K).
•
With installed sliding switch and control lamp for nighttime temperature reduction (4 K).
•
Servo valves of "closed when de-energized“ design are required for the controller.
… UF
•
With normally closed contact
•
With remote sensor (external temperature sensor for mounting in the floor) and thermal feedback.
•
For electric underfloor heating
•
Opening of the relay contact, when the set temperature is reached.
1096 …
•
Opens when the set temperature is reached.
•
With separate connection for time-controlled reduction of nighttime temperature (4K).
•
With installed sliding switch and control lamp for nighttime temperature reduction (4 K).
•
Servo valves of "closed when de-energized“ design are required for the controller.
1097 …
•
With switchover contact (heating / cooling)
•
Servo valves of "closed when de-energized“ design are required for the controller.
… UTA
•
With display of actual temperature
- Temperature display in steps of 0.5°C
•
Display accuracy: ±0,5°C for load currents
of ≤2 A
– Display accuracy: ±1,5°C for load currents of >2 A
•
Automatic controller calibration
Pos: 24 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenu+++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1