81
Attachments
EN
11.3 Prefabricated foundation - Terra 60
The drawing shows all the necessary measurements of the prefabricated foundation:
NOTE
On the top side of the prefabricated foundation an arrow indicates the front side.
NOTE
Each side has a square hole XxY = 237 x 165 mm to fit the conduits 1 x 160 mm and 1 x 75 mm
diameters or different combinations.
100
500
680
414
222
626
106
C
SECTION B-B
165
237
165
554
600
165
R3
237
181
159
500
106
288
B
B
opening for
conduit 160 + 75
160
160
87
506
70
2
DETAIL C