Illustration, PROFINET anybus device DSQC 688
xx0800000136
Network status LED
NS
Module status LED
MS
Link/Activity
LINK
RJ-45 connector
PROFINET IO
LEDs
This section describes the LEDs of the PROFINET anybus device.
Note
A test sequence is performed on the network status LED and on the module
status LED during start of the PROFINET anybus device.
Network status LED
Comments
Description
LED status
•
No power
•
No connection with a master
Offline
OFF
•
Connection with master established
•
Master in RUN state
Online (RUN)
Green
•
Connection with master established
•
Master in STOP state
Online (STOP)
Green, flashing
Module status LED
Comment
Description
LED status
Module not configured or no power.
Not initialized
OFF
Module is initialized.
Normal operation
GREEN
Diagnostic event(s) present.
Diagnostic event(s)
GREEN, 1 flash
Used by external configuration tools to identify
the node on the network.
Blink
GREEN, 2 flashes
Module in exception state.
Exception error
RED
Expected Identification differs from real identi-
fication.
Configuration error
RED, 1 flash
IP address not set.
IP address error
RED, 2 flashes
Device (Station) name not set.
Device name error
RED, 3 flashes
Module has encountered a major internal error.
Internal error
RED, 4 flashes
Continues on next page
20
Application manual - PROFINET Anybus Device
3HAC050968-001 Revision: C
© Copyright 2008-2016 ABB. All rights reserved.
2 Hardware overview
2.1 Main computer DSQC1000
Continued
Summary of Contents for 3HAC031670-001
Page 1: ...Application manual PROFINET Anybus Device ...
Page 6: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 22: ...This page is intentionally left blank ...
Page 34: ...This page is intentionally left blank ...
Page 42: ...This page is intentionally left blank ...
Page 44: ......
Page 45: ......