background image

0073-1-7524  │     │  22.02.2012 

  

ABB-Welcome 

 

 

 

Pos: 2 /DinA4 - Anleitungen Online/Inhalt/KNX/DoorEntry/83310/Titelblatt - 83310 - ABB @ 19\mod_1323174018866_15.docx @ 111018 @  @ 1 

 

83310-500 

83310-515 

Auxiliary power supply 

 

 

 

   

 

   

 

 

=== Ende der Liste für Textmarke Cover === 

 

Summary of Contents for 83310-500

Page 1: ... 02 2012 ABB Welcome Pos 2 DinA4 Anleitungen Online Inhalt KNX DoorEntry 83310 Titelblatt 83310 ABB 19 mod_1323174018866_15 docx 111018 1 83310 500 83310 515 Auxiliary power supply Ende der Liste für Textmarke Cover ...

Page 2: ...5 docx 109653 1 1 Safety 3 2 Intended use 3 3 Environment 3 3 1 ABB devices 3 4 User Manual 3 5 Operation 4 5 1 Standard operation 4 5 2 Adjusting the device 5 5 2 1 Terminal resistor 5 6 Technical data 6 7 Mounting Installation 7 7 1 Requirements for the electrician 7 7 2 General installation instructions 7 7 3 Mounting 8 7 4 Connection 8 Ende der Liste für Textmarke TOC ...

Page 3: ...eis Umwelt Hinweis Elektrogeräte 18 mod_1302763973434_15 docx 103500 1 C ons ider the protection of the environment Used electric and electronic devices must not be disposed of with domestic waste The device contains valuable raw materials which can be recycled Therefore dispose of the device at the appropriate collecting depot Pos 12 DinA4 Anleitungen Online Ueberschriften 2 ABB Geraete 19 mod_13...

Page 4: ...e 5 The terminal resistor is switched off The terminal resistor is switched on 2 Status LED The status LED lights up permanently the device is operating The status LED flashes slowly the device is operating The status LED flashes fast there is an error 3 Connection for the system controller When using several indoor stations connection for the internal bus 4 Indoor stations max 4 pairs of wires Co...

Page 5: ...Online Inhalt KNX DoorEntry Bedienung Abschlusswiderstand setzen 83310 xxx 19 mod_1312372134009_15 docx 108373 1 Fig 2 Setting the terminal resistor on the device In pure audio installations always set the terminal resistor 1 on OFF In video installations or mixed audio and video installations set the terminal resistor for the the last devices of a branch on ON Pos 24 Busch Jaeger Neustruktur Modu...

Page 6: ...e Operating temperature 5 C 45 C EN 50486 Storage temperature 20 C 70 C Protection IP 20 Connection cross section for 230 V Single wire clamps 2 x 0 6 mm 2 x 1 mm Fine wire clamps 2 x 0 6 mm 2 x 0 75 mm Volume Maximum 80 dB Mains voltage 100 240 V 50 60 Hz 0 9 A Indoor stations for direct connection 4 Size 8 TE Bus voltage 28 V 2 V Pos 27 Busch Jaeger Neustruktur Modul Struktur Online Dokumentatio...

Page 7: ...lows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect from power 2 Secure against being re connected 3 Ensure there is no voltage 4 Connect to earth 5 Cover or barricade adjacent live parts Use suitable personal protective clothing Use only suitable tools and measuring devices Check the type supply network TN system IT system TT system to secure the following power supply conditions ...

Page 8: ... on mounting rails according to DIN EN 500022 Pos 35 DinA4 Anleitungen Online Ueberschriften 2 Anschluss 18 mod_1302617573351_15 docx 103449 2 1 7 4 C onnection Pos 36 DinA4 Anleitungen Online Inhalt KNX DoorEntry 83310 Anschluss 83310 18 mod_1303216853127_15 docx 103779 1 Fig 3 No Function 1 Connection for the system controller When using several indoor stations connection for the internal bus 2 ...

Page 9: ... We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice The detailed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The docum...