ABB-Welcome 

 

Technical data

 

 

 

 

 

 

 

 

 

 

 

 

 

  | 0073-1-7519 

— 6 — 

   

Pos: 25 /DinA4 - Anleitungen Online/Ueberschriften/1./Technische Daten @ 18\mod_1302615863001_15.docx @ 103416 @ 1 @ 1 

 

Technical data 

 

Pos: 26 /DinA4 - Anleitungen Online/Inhalt/KNX/DoorEntry/83320-2-U/Technische Daten - 83320-2-U @ 18\mod_1303278243687_15.docx @ 104048 @  @ 1 

 

 

Des ignation 

V alue 

Operating temperature (EN 
50486) 

-5° C to +45° C 

Storage temperature 

-20°C – +70°C 

Protection 

IP 20 

Single-wire clamps 

2 x 0.6 mm² – 2 x 1 mm² 

Fine-wire clamps 

2 x 0.6 mm² – 2 x 0.75 mm² 

Bus voltage 

28 V- ±2 V 

 

Pos: 27 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenu+++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @  @ 1 

 

 

 

Summary of Contents for 83320/2 U-500

Page 1: ...ABB Welcome Pos 2 DinA4 Anleitungen Online Inhalt KNX DoorEntry 83320 2 U Titelblatt 83320 2 U ABB 19 mod_1323166421969_15 docx 110941 1 83320 2 U 500 83320 2 U 515 Video indoor distributor Ende der Liste für Textmarke Cover ...

Page 2: ...044386_15 docx 109653 1 1 Safety 3 2 Intended use 3 3 Environment 3 3 1 ABB devices 3 4 User Manual 3 5 Operation 4 5 1 Standard operation 4 5 2 Adjusting the device 5 5 2 1 Terminal resistor 5 6 Technical data 6 7 Mounting Installation 7 7 1 Requirements for the electrician 7 7 2 General installation instructions 7 7 3 Mounting 8 Ende der Liste für Textmarke TOC ...

Page 3: ... Hinweis Umwelt Hinweis Elektrogeräte 18 mod_1302763973434_15 docx 103500 1 C ons ider the protection of the environment Used electric and electronic devices must not be disposed of with domestic waste The device contains valuable raw materials which can be recycled Therefore dispose of the device at the appropriate collecting depot Pos 12 DinA4 Anleitungen Online Ueberschriften 2 ABB Geraete 19 m...

Page 4: ...dienung 83320 2 U 18 mod_1303278242828_15 docx 104016 1 Fig 1 No Function 1 Connection for the system controller When using several indoor stations connection for the internal bus 2 Switch for the terminal resistor see also chapter Terminal resistor on page 5 The terminal resistor is switched on The terminal resistor is switched off 3 4 Connections for the indoor stations Pos 20 Busch Jaeger Neust...

Page 5: ...Online Inhalt KNX DoorEntry Bedienung Abschlusswiderstand setzen 83320 2 U 19 mod_1311073974809_15 docx 107891 1 Fig 2 Setting the terminal resistor on the device In pure audio installations always set the terminal resistor 1 on OFF In video installations or mixed audio and video installations set the terminal resistor for the the last devices of a branch on ON Pos 24 Busch Jaeger Neustruktur Modu...

Page 6: ...che Daten 83320 2 U 18 mod_1303278243687_15 docx 104048 1 Des ignation Value Operating temperature EN 50486 5 C to 45 C Storage temperature 20 C 70 C Protection IP 20 Single wire clamps 2 x 0 6 mm 2 x 1 mm Fine wire clamps 2 x 0 6 mm 2 x 0 75 mm Bus voltage 28 V 2 V Pos 27 Busch Jaeger Neustruktur Modul Struktur Online Dokumentation Steuermodule Online Dokumentation Für alle Dokumente Seitenumbruc...

Page 7: ...lows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect from power 2 Secure against being re connected 3 Ensure there is no voltage 4 Connect to earth 5 Cover or barricade adjacent live parts Use suitable personal protective clothing Use only suitable tools and measuring devices Check the type supply network TN system IT system TT system to secure the following power supply conditions ...

Page 8: ... Online Inhalt Montage Montage UP Dosen DIN 49073 1 oder geeignetes Aufputzgehaeuse 19 mod_1313415304041_15 docx 108713 1 The device 83320 2 U 500 must only be installed in suitable FM boxes DIN 49073 1 or a suitable surface mounted housing Pos 35 Busch Jaeger Neustruktur Modul Struktur Online Dokumentation Steuermodule Online Dokumentation Für alle Dokumente Seitenumbruch 9 mod_1268898668093_0 do...

Page 9: ... We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice The detailed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The docum...

Reviews: