Operation Manual / 4 Product description / A130-M.. - A145-M..
5 Operation and service / 5.3 Expected replacement intervals
© Copyright 2019 ABB. All rights reserved.
HZTL4031_EN
Revision H
March 2019
Influencing parameters
The specified values are guideline values and are not guaranteed. The actual values can devi-
ate considerably from the guideline values, for example, due to the following influences:
¡
Fuel quality and fuel treatment
¡
Load profile (thermal cycling, also number of starts/stops, emergency shutdowns, oper-
ating point)
¡
Gas inlet temperature
¡
Frequency and execution of cleaning process during operation
¡
Turbocharger specification.
¡
System-specific operating conditions (combustion quality, exhaust gas composition)
For bearing parts
¡
Lubricating oil quality (oil filtering, oil condition, oil monitoring)
¡
Load profile (speed, pressure conditions, temperature)
¡
Number of starts/stops
¡
Unbalance of the rotor (degree of contamination).
Page
40
/
113