05 Types of Devices
ABB-free@home
®
58
│
System Manual
Master reset without access to the Web
interface
Attention! All data will be lost
A master reset is carried out as follows:
»
Lift the cover off the System Access Point.
»
Briefly press the reset button (above the bus connec-
tion terminal).
»
During the boot-up process, which starts now, simul-
taneous press all three buttons until all three LEDs
light up. This can take up to a minute.
The System Access Point is then back to its factory set-
tings.
Additional general settings in the System
Access Point
System information
Current software version status.
Network
Here the network settings of the System Access Point can
be programmed.
Possible settings:
»
LAN client - Used when the System Access Point is
connected to the Internet router via network cable.
Note: This mode is activated automatically when the
access point mode is deactivated (LED of the left but-
ton is off).
»
WLAN client - Used when the System Access Point is
connected to the Internet router via WLAN.
User
Her additional users can be created or users deleted. Also
access rights can be changed.
General
Setting of the system name, the system language, loca-
tion and time.
Data backup
The data backup stores all the settings made. It is first
backed up on the internal memory of the System Access
Point, but it can also be exported. The data backup is
created automatically at regular intervals, but it can also
be created manually. Data backups that have been creat-
ed by user type "Fitter", can be restored by other users,
but cannot be deleted by them.
Summary of Contents for ABB-free home
Page 1: ...ABB free home System Manual ...
Page 2: ...2 System Manual ...
Page 19: ...ABB free home 04 Commissioning System Manual 19 Fig 13 Basic settings ...
Page 33: ...ABB free home 04 Commissioning System Manual 33 Fig 28 Panel ...
Page 75: ...ABB free home 08 FAQ und Tipps System Manual 75 ...