Resetting the Device
Product Manual 2CQA 100 001 B0001
│
2018-09-28
│
10
5
Resetting the Device
Reset the Light Switch if it was previously assigned to a different System Access Point (SysAP).
The reset will remove any previous connection and enable the device to connect to a new
SysAP.
Reset procedure:
A) Press and hold the bottom of the rocker for at least 20 seconds.
B) The bottom LED light will start flashing after 10 seconds.
C) After another 5 seconds, the LED will start flashing rapidly. After another 5 seconds, the LED
light will turn off.
D) Release the bottom of the rocker within the next 10 seconds.
E) Then press the bottom of the rocker. The lower LED light will stay on. Press the bottom of the
rocker again. The previous actions must be completed within 5 seconds.
F) The device will now return to factory settings and restart.