3.
Place the mounting pad between the motor fins in the desired location. Make
sure that:
•
correct motor fin mount type is used.
•
the probe is fixed between the motor fins, and the bottom of the probe is
in contact with the motor casing.
4. Press the mounting pad firmly. Make sure that:
•
bottom of mounting pad touches the motor casing, which is the contact
area to transfer vibration from motor to sensor.
•
tip of motor fin mount pad is flat against the motor casing (item 3 in below
figure) as possible.
•
mounting pad is not resting on top of the fins. If it rests on top of the fins,
make sure the bottom of the probe is not in direct contact with the motor
casing. See the below example mounting positions:
Incorrect mounting
Correct mounting
Voids filled with adhesive
1
Motor fins
2
Contact point
3
Motor casing
4
Note: The mounting pads are not included in the package. You must order
them separately.
Mount the sensors
Mount the accelerometers on the mounting pads with screws into the pad or
triaxial mounting base.
Recommended mounting torque: 2.7 Nm to 6.8 Nm
40 Installing the accelerometers
Summary of Contents for Ability MACHsense-R
Page 1: ...ABB MOTION SERVICES ABB Ability MACHsense R MSR1608 Data acquisition unit User manual...
Page 2: ......
Page 4: ......
Page 8: ...8...
Page 12: ...12...
Page 18: ...18...
Page 20: ...Process overview diagram 20 Getting started...
Page 26: ...26...
Page 34: ...34...
Page 42: ...42...
Page 46: ...46...
Page 50: ...50...
Page 58: ...58...
Page 66: ...66...