Overview of product range
System Manual 2CKA001473B5074
│28
2.3.8
Dismantling old cylindrical locks
Aside from the normal local standard cylinders, also other cylinder systems are used when the
situation requires it. If for the use of the "ABB-AccessControl" old cylindrical locks must be
removed, you will find information in the following about the dismantling of conventional
cylindrical locks.
Dismantling old cylinders: Profile Europe (EU) and Switzerland (CH)
2.
3.
1.
Fig. 15: Dismantling old cylinders: Profile Europe (EU) and Switzerland (CH)
To dismantle the existing old cylinders, perform the following items:
1. Turn the driver down vertically.
2. Screw out the forend screw.
3. Remove the cylinder.
Dismantling old cylinders: Profile Scandinavian oval
1.
2.
3.
Fig. 16: Dismantling old cylinders: Profile Scandinavian oval
To dismantle the existing old cylinders, perform the following items:
1. Dismantle the head on the interior side.
2. Dismantle the mounting set of the cylindrical lock on the interior side.
3. Remove the cylinder on the exterior side.