ACH580 Installation, Operation and Maintenance Manual
25
ACH580-01 Installation
UL (NEC) ratings at U
N
= 575 V
Definitions
ACH580-01-180A-4
180
2346
265
R7
ACH580-01-240A-4
240
3336
324
R8
ACH580-01-302A-4
302
4836
677
R9
ACH580-01-361A-4
361
6036
677
R9
ACH580-01-414A-4
414
6036
677
R9
Type
Output ratings
Heat
dissipation
Air
flow
Frame
size
A
W
ft
3
/min
ACH580-01-02A7-6
2.7
66
59
R2
ACH580-01-03A9-6
3.9
84
59
R2
ACH580-01-06A1-6
6.1
133
59
R2
ACH580-01-09A0-6
9
174
59
R2
ACH580-01-011A-6
11
228
59
R2
ACH580-01-017A-6
17
322
59
R2
ACH580-01-022A-6
22
430
105
R3
ACH580-01-027A-6
27
525
105
R3
ACH580-01-032A-6
32
619
105
R3
ACH580-01-041A-6
41
835
82
R5
ACH580-01-052A-6
52
1024
82
R5
ACH580-01-062A-6
62
1240
82
R5
ACH580-01-077A-6
77
1510
82
R5
ACH580-01-099A-6
99
2061
265
R7
ACH580-01-125A-6
125
2466
265
R7
ACH580-01-144A-6
144
3006
324
R8
ACH580-01-192A-6
156
4086
677
R9
ACH580-01-242A-6
242
4896
677
R9
ACH580-01-271A-6
271
4896
677
R9
U
N
Output voltage of the drive.
I
Continuous rms output current, allowing 110% overload for 1
minute every 10
minutes.
P
Typical motor power
Type
Output ratings
Heat
dissipation
Air
flow
Frame
size
A
W
ft
3
/min
ACH580_Inst_Op_Maint_Rev G.book Page 25