IEC
Frame
Noise
Air flow
Heat dissipation
ACH580-
31-…
Main cir-
cuit and
control
boards
Control
circuit
maxim-
um
Control
circuit
minim-
um
Main cir-
cuit at
rated
I1
at
I2
dB(A)
ft3/min
m3/h
W
W
W
W
R3
57
212
361
219
36
4.1
183
09A5-4
R3
57
212
361
278
36
4.1
242
12A7-4
R3
57
212
361
321
36
4.1
285
018A-4
R3
57
212
361
473
36
4.1
437
026A-4
R6
65
212
361
625
36
4.1
589
033A-4
R6
71
324
550
711
36
4.1
675
039A-4
R6
71
324
550
807
36
4.1
771
046A-4
R6
71
324
550
960
36
4.1
924
062A-4
R6
71
324
550
1223
36
4.1
1187
073A-4
R6
71
324
550
1560
36
4.1
1524
088A-4
R8
68
1678
36
4.1
1642
106A-4
R8
68
2237
36
4.1
2201
145A-4
R8
68
2796
36
4.1
2760
169A-4
R8
68
3356
36
4.1
3320
206A-4
1) IP21/IP55
These losses are not calculated according to the ecodesign standard IEC 61800-9-2.
UL (NEC)
Frame
Noise
Air flow
Heat dissipation
ACH580-
31-…
Main cir-
cuit and
control
boards
Control
circuit
maxim-
um
Control
circuit
minim-
um
Main cir-
cuit at
rated
I1
at
I2
dB(A)
ft3/min
m3/h
W
W
W
W
Un = 480 V
R3
57
212
361
219
36
4.1
183
07A6-4
R3
57
212
361
278
36
4.1
242
012A-4
R3
57
212
361
321
36
4.1
285
014A-4
R3
57
212
361
473
36
4.1
437
023A-4
R6
71
32
550
625
36
4.1
589
027A-4
R6
71
324
550
711
36
4.1
675
034A-4
R6
71
324
550
807
36
4.1
771
044A-4
R6
71
324
550
960
36
4.1
924
052A-4
Technical data 191
Summary of Contents for ACH580-31
Page 1: ... ABB INDUSTRIAL DRIVES ACH580 31 drives Hardware manual ...
Page 2: ......
Page 4: ......
Page 16: ...16 ...
Page 30: ...30 ...
Page 39: ...Operation principle 39 ...
Page 56: ...56 ...
Page 90: ...90 ...
Page 112: ...R3 1 7 N m 112 Electrical installation IEC ...
Page 113: ...R6 1 7 N m Electrical installation IEC 113 ...
Page 114: ...R8 1 7 N m 114 Electrical installation IEC ...
Page 130: ...R3 Max 250 mA 130 Electrical installation North America NEC ...
Page 131: ...R6 Electrical installation North America NEC 131 ...
Page 150: ...150 ...
Page 152: ...152 ...
Page 166: ... Fan arrow must point up 166 Maintenance ...
Page 212: ...212 ...
Page 214: ...R3 IP21 UL Type 1 3AXD50000028643 214 Dimension drawings ...
Page 215: ...R3 Option B056 IP55 UL Type 12 3AXD50000045321 Dimension drawings 215 ...
Page 216: ...R6 IP21 UL Type 1 3AXD50000037446 216 Dimension drawings ...
Page 217: ...R6 Option B056 IP55 UL Type 12 3AXD50000045351 Dimension drawings 217 ...
Page 218: ...R8 IP21 UL Type 1 3AXD50000147052 218 Dimension drawings ...
Page 219: ...R8 Option B056 IP55 UL Type 12 3AXD50000147052 Dimension drawings 219 ...
Page 220: ...220 ...
Page 242: ...242 ...
Page 250: ...250 ...
Page 254: ...254 ...
Page 262: ...262 ...
Page 268: ...268 ...
Page 275: ...CMOD 01 multifunction extension module external 24 V AC DC and digital I O 275 ...
Page 276: ...276 ...
Page 282: ...282 CMOD 02 multifunction extension module external 24 V AC DC and isolated PTC interface ...