IEC
Frame
Air flow (C135)
Heat dissipation (op-
tion +C135)
ACH580-
31-…
Front
Heatsink
Front
Heatsink
ft3/min
m3/h
ft3/min
m3/h
W
W
R3
0
0
212
361
39
144
09A5-4
R3
0
0
212
361
40
202
12A7-4
R3
0
0
212
361
41
244
018A-4
R3
0
0
212
361
44
393
026A-4
R6
31
52
293
498
47
542
033A-4
R6
31
52
293
498
48
627
039A-4
R6
31
52
293
498
50
721
046A-4
R6
31
52
293
498
53
871
062A-4
R6
31
52
293
498
59
1128
073A-4
R6
31
52
293
498
66
1458
088A-4
R8
66
113
471
800
69
1573
106A-4
R8
66
113
471
800
84
2117
145A-4
R8
66
113
471
800
100
2660
169A-4
R8
66
113
471
800
118
3201
206A-4
Un = 480 V
R3
0
0
212
361
39
144
07A6-4
R3
0
0
212
361
40
202
012A-4
R3
0
0
212
361
41
244
014A-4
R3
0
0
212
361
44
393
023A-4
R6
31
52
293
498
47
542
027A-4
R6
31
52
293
498
48
627
034A-4
R6
31
52
293
498
50
721
044A-4
R6
31
52
293
498
53
871
052A-4
R6
31
52
293
498
59
1128
065A-4
R6
31
52
293
498
66
1458
077A-4
R8
66
113
471
800
69
1573
096A-4
R8
66
113
471
800
84
2117
124A-4
R8
66
113
471
800
100
2660
156A-4
R8
66
113
471
800
118
3201
180A-4
These losses are not calculated according to the ecodesign standard IEC 61800-9-2.
Technical data 193
Summary of Contents for ACH580-31
Page 1: ... ABB INDUSTRIAL DRIVES ACH580 31 drives Hardware manual ...
Page 2: ......
Page 4: ......
Page 16: ...16 ...
Page 30: ...30 ...
Page 39: ...Operation principle 39 ...
Page 56: ...56 ...
Page 90: ...90 ...
Page 112: ...R3 1 7 N m 112 Electrical installation IEC ...
Page 113: ...R6 1 7 N m Electrical installation IEC 113 ...
Page 114: ...R8 1 7 N m 114 Electrical installation IEC ...
Page 130: ...R3 Max 250 mA 130 Electrical installation North America NEC ...
Page 131: ...R6 Electrical installation North America NEC 131 ...
Page 150: ...150 ...
Page 152: ...152 ...
Page 166: ... Fan arrow must point up 166 Maintenance ...
Page 212: ...212 ...
Page 214: ...R3 IP21 UL Type 1 3AXD50000028643 214 Dimension drawings ...
Page 215: ...R3 Option B056 IP55 UL Type 12 3AXD50000045321 Dimension drawings 215 ...
Page 216: ...R6 IP21 UL Type 1 3AXD50000037446 216 Dimension drawings ...
Page 217: ...R6 Option B056 IP55 UL Type 12 3AXD50000045351 Dimension drawings 217 ...
Page 218: ...R8 IP21 UL Type 1 3AXD50000147052 218 Dimension drawings ...
Page 219: ...R8 Option B056 IP55 UL Type 12 3AXD50000147052 Dimension drawings 219 ...
Page 220: ...220 ...
Page 242: ...242 ...
Page 250: ...250 ...
Page 254: ...254 ...
Page 262: ...262 ...
Page 268: ...268 ...
Page 275: ...CMOD 01 multifunction extension module external 24 V AC DC and digital I O 275 ...
Page 276: ...276 ...
Page 282: ...282 CMOD 02 multifunction extension module external 24 V AC DC and isolated PTC interface ...