European Union and United Kingdom
To comply with European Union directives and United Kingdom regulations related
to standard EN 60204-1, the disconnecting device must be one of these types:
•
switch-disconnector of utilization category AC-23B (IEC 60947-3)
•
disconnector that has an auxiliary contact that in all cases causes switching
devices to break the load circuit before the opening of the main contacts of
the disconnector (EN 60947-3)
•
circuit-breaker suitable for isolation in accordance with IEC 60947-2.
■
North America
Installations must be compliant with NFPA 70 (NEC)
1)
and/or Canadian Electrical
Code (CE) along with state and local codes for your location and application.
1)
National Fire Protection Association 70 (National Electric Code).
■
Other regions
The disconnecting device must conform to the applicable local safety regulations.
Implementing a fast switch over between the power line and
generator
You can do a fast switch over between the power line and generator without
stopping the drive. Starting and stopping the drive takes more time than the fast
switch over.
WARNING! The drive requires at least a 50 ms fast switch over time and the
same phase order in the switching. A shorter switch over time or a different
phase order can cause a drive fault trip or damage to the drive.
Consult ABB for implementation instructions of the fast switch over system.
Selecting the main contactor
You can equip the drive with a main contactor.
Follow these guidelines when you select a customer-defined main contactor:
•
Dimension the contactor according to the nominal voltage and current of the
drive. Also consider the environmental conditions such as surrounding air
temperature.
•
IEC devices only: Select contactor with utilization category AC-1 (number of
operations under load) according to IEC 60947-4.
•
Consider the application life time requirements.
58 Guidelines for planning the electrical installation
Summary of Contents for ACH580-31
Page 1: ... ABB INDUSTRIAL DRIVES ACH580 31 drives Hardware manual ...
Page 2: ......
Page 4: ......
Page 16: ...16 ...
Page 30: ...30 ...
Page 39: ...Operation principle 39 ...
Page 56: ...56 ...
Page 90: ...90 ...
Page 112: ...R3 1 7 N m 112 Electrical installation IEC ...
Page 113: ...R6 1 7 N m Electrical installation IEC 113 ...
Page 114: ...R8 1 7 N m 114 Electrical installation IEC ...
Page 130: ...R3 Max 250 mA 130 Electrical installation North America NEC ...
Page 131: ...R6 Electrical installation North America NEC 131 ...
Page 150: ...150 ...
Page 152: ...152 ...
Page 166: ... Fan arrow must point up 166 Maintenance ...
Page 212: ...212 ...
Page 214: ...R3 IP21 UL Type 1 3AXD50000028643 214 Dimension drawings ...
Page 215: ...R3 Option B056 IP55 UL Type 12 3AXD50000045321 Dimension drawings 215 ...
Page 216: ...R6 IP21 UL Type 1 3AXD50000037446 216 Dimension drawings ...
Page 217: ...R6 Option B056 IP55 UL Type 12 3AXD50000045351 Dimension drawings 217 ...
Page 218: ...R8 IP21 UL Type 1 3AXD50000147052 218 Dimension drawings ...
Page 219: ...R8 Option B056 IP55 UL Type 12 3AXD50000147052 Dimension drawings 219 ...
Page 220: ...220 ...
Page 242: ...242 ...
Page 250: ...250 ...
Page 254: ...254 ...
Page 262: ...262 ...
Page 268: ...268 ...
Page 275: ...CMOD 01 multifunction extension module external 24 V AC DC and digital I O 275 ...
Page 276: ...276 ...
Page 282: ...282 CMOD 02 multifunction extension module external 24 V AC DC and isolated PTC interface ...