194 Parameters
02.15
EFB MAIN CW
Internal Control Word of the drive received through
the embedded fieldbus interface.
Log. = Logical combination (i.e. Bit AND/OR Selection
parameter); Par. = Selection parameter.
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Bit
Name
Value Information
Log. Par.
0
STOP*
1
Stop according to the Stop mode selected by
parameters
DOWN COMMAND or according to the
requested stop mode (bits 2…6).
Note:
Simultaneous stop and start commands
result in a stop command.
OR
0
No action.
1
START
1
Start.
Note:
Simultaneous stop and start commands
result in a stop command.
OR
0
No action.
2
STPMODE
EM OFF*
1
Emergency OFF2 (bit 0 must be 1): Drive is
stopped by cutting off the motor power supply
(the inverter IGBTs are blocked). The motor
coasts to stop. The drive will restart only with
the next rising edge of the start signal when
the Run enable signal is on.
AND
–
0
No action.
3
STPMODE
EM STOP*
1
Emergency stop OFF3 (bit 0 must be 1). Stop
within the time defined by
EM STOP
TIME.
AND
–
0
No action.
4
STPMODE
OFF1*
1
Emergency stop OFF1 (bit 0 must be 1). Stop
along the currently active deceleration ramp.
AND
0
No action.
5
STPMODE
RAMP*
1
Stop along the currently active deceleration
ramp.
–
0
No action.
6
STPMODE
COAST*
1
Coast to stop.
–
0
No action.
7
RUN
ENABLE
1
Activate Run enable.
AND
–
0
Activate Run disable.
8
RESET
0 -> 1 Fault reset if an active fault exists.
OR
–
other No action.
(continued)
* If all stop mode bits 2…6 are 0, stop mode is ramp. Coast stop (bit 6) overrides the
emergency stop (bits 2/3/4). Emergency stop overrides the normal ramp stop (bit 5).
Summary of Contents for ACL30
Page 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 34: ...34 Operation principle and hardware description ...
Page 42: ...42 Planning the cabinet installation ...
Page 60: ...60 Planning the electrical installation ...
Page 126: ...126 Using the control panel ...
Page 318: ...318 Maintenance ...
Page 334: ...334 The Safe torque off function ...
Page 338: ...338 Mains chokes ...
Page 342: ...342 EMC filters ...
Page 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Page 349: ...Dimension drawings 349 ...
Page 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Page 351: ...Dimension drawings 351 ...
Page 352: ...Dimension drawings 352 Frame size D ...
Page 354: ...354 Dimension drawings EMC filters JFI 0x ...
Page 356: ...356 Dimension drawings Brake resistors JBR xx ...
Page 358: ...358 Dimension drawings ...