Parameters 207
08.03
FAULT TIME HI
Shows the time (real time or power-on time) at which
the active fault occurred in format dd.mm.yy
(=day.month.year).
0...2147483647
days
Number of days.
- / 1 = 1
08.04
FAULT TIME LO
Shows the time (real time or power-on time) at which
the active fault occurred in format hh.mm.ss
(hours.minutes.seconds).
00.00.00...
2147483647
Time (in hours.minutes.seconds)
- / 1 = 1
08.05
ALARM LOGGER 1
Alarm logger 1. For possible causes and remedies,
see chapter
.
0x0000...0xFFFF Alarm logger 1
1 = 1 / -
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Bit
Alarm
0
BRAKE START TORQ
1
BRAKE NOT CLOSED
2
BRAKE NOT OPEN
3
SAFE TORQUE OFF
4
STO MODE CHANGE
5
MOTOR TEMP
6
EMERGENCY OFF
7
RUN ENABLE
8
MOTOR ID-RUN
9
EMERGENCY STOP
10
RESERVED
11
BR OVERHEAT
12
BC OVERHEAT
13
DEVICE OVERTEMP
14
INTBOARD OVERTEM
15
BC MOD OVERTEMP
Summary of Contents for ACL30
Page 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 34: ...34 Operation principle and hardware description ...
Page 42: ...42 Planning the cabinet installation ...
Page 60: ...60 Planning the electrical installation ...
Page 126: ...126 Using the control panel ...
Page 318: ...318 Maintenance ...
Page 334: ...334 The Safe torque off function ...
Page 338: ...338 Mains chokes ...
Page 342: ...342 EMC filters ...
Page 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Page 349: ...Dimension drawings 349 ...
Page 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Page 351: ...Dimension drawings 351 ...
Page 352: ...Dimension drawings 352 Frame size D ...
Page 354: ...354 Dimension drawings EMC filters JFI 0x ...
Page 356: ...356 Dimension drawings Brake resistors JBR xx ...
Page 358: ...358 Dimension drawings ...