236 Parameters
AI1
Speed reference from analogue input AI1.
1
AI2
Speed reference from analogue input AI2.
2
FBA REF1
Speed reference from fieldbus reference 1.
3
FBA REF2
Speed reference from fieldbus reference 2.
4
EFB REF1
Speed reference from EFB reference 1.
5
EFB REF2
Speed reference from EFB reference 2.
6
22.05
SPEED SCALING
Internally used. Cannot be set by the user.
Shows the motor rotational speed (rpm), which
corresponds to the lift nominal speed (m/s) defined
with parameter
NOMINAL SPEED. The
parameter value is calculated based on the lift
nominal speed, gear ratio, roping ratio and sheave
diameter. See also section
on page
Also defines the rpm value that corresponds to
20000 for fieldbus communication with ABB Drives
communication profile.
0...30000 rpm
Speed scaling value.
1 = 1 rpm
22.06
EM STOP TIME
Defines the time within which the drive is stopped if
an emergency stop OFF3 is activated (ie, the time
required for the speed to change from the speed
value defined by parameter
SPEED SCALING
to zero). The emergency stop OFF3 is activated if the
Final limit switches or Leveling overtime stop function
becomes active. See also section
on page
Emergency stop OFF1 uses the active ramp time.
1.000 s /
0.000…
1800.000 s
Emergency stop OFF3 deceleration time.
- /
1000 = 1 s
25
25 ACC/DEC
RAMP
Speed reference ramp settings.
25.80
ACC/DEC SEL
Selects the source for the acceleration/deceleration
set 1 or acceleration/deceleration set 2 used in the
normal travel mode.
1 = Acc/dec set 2 is used.
0 = Acc/dec set 1 is used.
For more information, see section
Acceleration/deceleration selection
on page
.
C.False/
Bit pointer: CONST or POINTER (See
.)
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Summary of Contents for ACL30
Page 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 34: ...34 Operation principle and hardware description ...
Page 42: ...42 Planning the cabinet installation ...
Page 60: ...60 Planning the electrical installation ...
Page 126: ...126 Using the control panel ...
Page 318: ...318 Maintenance ...
Page 334: ...334 The Safe torque off function ...
Page 338: ...338 Mains chokes ...
Page 342: ...342 EMC filters ...
Page 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Page 349: ...Dimension drawings 349 ...
Page 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Page 351: ...Dimension drawings 351 ...
Page 352: ...Dimension drawings 352 Frame size D ...
Page 354: ...354 Dimension drawings EMC filters JFI 0x ...
Page 356: ...356 Dimension drawings Brake resistors JBR xx ...
Page 358: ...358 Dimension drawings ...