Parameters 261
58.32
WORD ORDER
Defines the order of the data words in the Modbus
frame.
LSW MSW /
MSW LSW
Most significant word first, then Least significant
word.
0
LSW MSW
Least significant word first, then Most significant
word.
1
58.35
DATA I/O 1
Defines the address of the drive parameter which the
Modbus master accesses when it reads from or
writes to the register address corresponding to
Modbus In/Out parameter no. 1. The Modbus master
defines the type of the data (input or output).
The value is conveyed in a Modbus frame using two
16-bit words. If the drive parameter is a 16-bit value,
the LSW (Least significant word) conveys the value.
If the drive parameter is a 32-bit value, the next
Modbus In/Out parameter is also RESERVED.
0…9999
Parameter address. Format: xxyy, where:
xx = parameter group
yy = parameter index
1 = 1
58.36
DATA I/O 2
See parameter
0…9999
See parameter
1 = 1
…
…
…
…
58.58
DATA I/O 24
See parameter
0…9999
See parameter
1 = 1
72
72 INTERNALLY
USED
Internally used. Cannot be set by the user.
72.01
JOG1 START
Internally used. Cannot be set by the user.
72.02
FAULT RESET SEL
Internally used. Cannot be set by the user.
72.03
EM STOP OFF3
Internally used. Cannot be set by the user.
72.04
FB CW USED
Selects the source for the control word when fieldbus
(FBA) is selected as the start and stop control
location (see parameter
START FUNC). By
default, the source is from parameter
FBA
MAIN CW.
Note:
This parameter cannot be changed while the
drive is running.
P.FBA MAIN
CW/
Value pointer (See
72.05
JOG2 START
Internally used. Cannot be set by the user.
72.06
JOG ENABLE
Internally used. Cannot be set by the user.
72.07
START ENABLE
Internally used. Cannot be set by the user.
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Summary of Contents for ACL30
Page 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 34: ...34 Operation principle and hardware description ...
Page 42: ...42 Planning the cabinet installation ...
Page 60: ...60 Planning the electrical installation ...
Page 126: ...126 Using the control panel ...
Page 318: ...318 Maintenance ...
Page 334: ...334 The Safe torque off function ...
Page 338: ...338 Mains chokes ...
Page 342: ...342 EMC filters ...
Page 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Page 349: ...Dimension drawings 349 ...
Page 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Page 351: ...Dimension drawings 351 ...
Page 352: ...Dimension drawings 352 Frame size D ...
Page 354: ...354 Dimension drawings EMC filters JFI 0x ...
Page 356: ...356 Dimension drawings Brake resistors JBR xx ...
Page 358: ...358 Dimension drawings ...