264 Parameters
80.08
SPEED REF SEL3
Selects the source for speed reference selection
pointer 3. The bit combination of parameters
,
determines the speed
reference when neither the evacuation mode nor the
inspection mode is active.
DI6/
Bit pointer: CONST or POINTER (See
.)
80.09
SPEED REF SEL4
Selects the source for speed reference selection
pointer 4. The bit combination of parameters
,
determines the speed
reference when neither the evacuation mode nor the
inspection mode is active.
NOT USED/
Bit pointer: CONST or POINTER (See
.)
80.10
SPEED1
A factory-set zero speed reference (0 m/s) to be
used when the bit combination of parameters
,
is 000. Can be used for stopping the
lift in the normal travel mode. Cannot be set by the
user.
This parameter is read-only.
0.00 m/s /
0.00...25.00 m/s
Speed reference
100 = 1 m/s
80.11
LEVELING SPEED
Defines the speed reference to be used during
leveling, ie, when the bit combination of parameters
is 110. When the floor switch
is hit, the drive decelerates to the leveling speed.
0.25 m/s /
0.00…25.00 m/s
Leveling speed reference.
100 = 1 m/s
80.12
RELVL SPEED SEL
Selects the source of the speed reference to be used
in the releveling mode. If the lift overshoots the floor
level, it is driven back to the floor level using the
releveling mode.
PAR 80.13 /
PAR 80.13
Parameter
RELEVELING SPEED selected as
the source of the releveling speed reference.
0
AI1 SCALED
AI1 signal (
AI1 SCALED) selected as the
source of the releveling speed reference.
1
AI2 SCALED
AI2 signal (
AI2 SCALED) selected as the
source of the releveling speed reference.
2
80.13
RELEVELING
SPEED
Defines the speed reference to be used in the
releveling mode when selected as the source of
parameter
RELVL SPEED SEL. Used when
the bit combination of parameters
is 001.
0.10 m/s /
0.00…25.00 m/s
Releveling speed reference.
100 = 1 m/s
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Summary of Contents for ACL30
Page 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 34: ...34 Operation principle and hardware description ...
Page 42: ...42 Planning the cabinet installation ...
Page 60: ...60 Planning the electrical installation ...
Page 126: ...126 Using the control panel ...
Page 318: ...318 Maintenance ...
Page 334: ...334 The Safe torque off function ...
Page 338: ...338 Mains chokes ...
Page 342: ...342 EMC filters ...
Page 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Page 349: ...Dimension drawings 349 ...
Page 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Page 351: ...Dimension drawings 351 ...
Page 352: ...Dimension drawings 352 Frame size D ...
Page 354: ...354 Dimension drawings EMC filters JFI 0x ...
Page 356: ...356 Dimension drawings Brake resistors JBR xx ...
Page 358: ...358 Dimension drawings ...