268 Parameters
81.09
LVL MAX TIME
Defines the maximum time the drive can run at the
leveling speed. If the stop command has not been
received before this time period elapses, the
Leveling overtime stop function activates an
emergency stop command (OFF3). The function is
enabled when the value of this parameter is > 0.
0.0 s /
0.0…25.0 s
Maximum leveling time for the Leveling overtime stop
function.
10 = 1 s
83
82 SMART
SLOWDOWN
Parameters related to the Smart slowdown function.
See also section
.
82.01
SMART SLOWDN
SEL
Enables/disables the Smart slowdown function.
NOT SEL /
NOT SEL
Smart slowdown function is not enabled.
0
ESTIMATED
Smart slowdown function is enabled with the
estimated speed. The distance traveled is calculated
by integrating the actual speed.
1
ENCODER
Smart slowdown function is enabled with an encoder.
The distance traveled is based on the actual position
of the encoder (
POS ACT).
2
82.02
LV STOP SWC
DIST
Defines the distance between leveling and stopping
switches.
0.00 m /
0.00…100.00 m
Distance between leveling and stopping switches.
100 = 1 m
82.03
SAFETY MARGIN
Defines what percentage of parameter
is used
as the safety distance when the Smart slowdown
function is enabled. Safety distance is the distance
which must be run with the steady state leveling
speed.
0.00 % /
0.00…100.00%
Safety margin in percentages.
100 = 1%
90
90 ENC MODULE
SEL
Settings for encoder activation, emulation, TTL echo,
and communication fault detection.
90.01
ENCODER SEL
Activates the communication to optional
encoder/resolver interface.
None /
None
Inactive.
0
FEN-01 TTL+
Communication active. Module type: FEN-01 TTL
Encoder interface Module. Input: TTL encoder input
with commutation support (X32). See parameter
group
1
FEN-01 TTL
Communication active. Module type: FEN-01 TTL
Encoder interface Module. Input: TTL encoder input
(X31). See parameter group
.
2
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Summary of Contents for ACL30
Page 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 34: ...34 Operation principle and hardware description ...
Page 42: ...42 Planning the cabinet installation ...
Page 60: ...60 Planning the electrical installation ...
Page 126: ...126 Using the control panel ...
Page 318: ...318 Maintenance ...
Page 334: ...334 The Safe torque off function ...
Page 338: ...338 Mains chokes ...
Page 342: ...342 EMC filters ...
Page 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Page 349: ...Dimension drawings 349 ...
Page 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Page 351: ...Dimension drawings 351 ...
Page 352: ...Dimension drawings 352 Frame size D ...
Page 354: ...354 Dimension drawings EMC filters JFI 0x ...
Page 356: ...356 Dimension drawings Brake resistors JBR xx ...
Page 358: ...358 Dimension drawings ...