280 Parameters
93.09
EMUL POS
OFFSET
Defines the zero point for emulated position in
relation of the zero point of the input position (within
one revolution). The input position is selected by
parameter
EMUL MODE SEL.
For example, if the offset is 0, an emulated zero
pulse is generated each time the input position
moves across 0. With an offset of 0.5, an emulated
zero pulse is generated each time the input position
(within one revolution) moves across 0.5.
0.00000 rev
/
0.00000
…0.99998 rev
Emulated zero pulse position offset.
- / 100000 =
1 rev
97
97 USER MOTOR
PAR
User adjustment of motor model values estimated
during ID run. The values can be entered in either
“per unit” or SI.
97.01
USE GIVEN
PARAMS
Activates the motor model parameters
and the rotor angle offset parameter
.
Notes:
• The parameter value is automatically set to zero
when ID run is selected by parameter
IDRUN MODE. The values of parameters
are updated according to the motor
characteristics identified during the ID run.
• This parameter cannot be changed while the drive
is running.
NoUserPars
/
NoUserPars
inactive.
0
UserMotPars
the motor model.
1
UserPosOffs
is used as the rotor
angle offset. Parameters
are inactive.
2
AllUserPars
the motor model, and the value of parameter
is
used as the rotor angle offset.
3
97.02
RS USER
Defines the stator resistance
R
S
of the motor model. 0.00000 p.u.
/
0.00000…
0.50000 p.u
Stator resistance.
- / 100000 =
1 p.u
97.03
RR USER
Defines the rotor resistance
R
R
of the motor model.
Note:
This parameter is valid only for asynchronous
motors.
0.00000 p.u.
/
0.00000…
0.50000 p.u
Rotor resistance.
- / 100000 =
1 p.u
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Summary of Contents for ACL30
Page 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 34: ...34 Operation principle and hardware description ...
Page 42: ...42 Planning the cabinet installation ...
Page 60: ...60 Planning the electrical installation ...
Page 126: ...126 Using the control panel ...
Page 318: ...318 Maintenance ...
Page 334: ...334 The Safe torque off function ...
Page 338: ...338 Mains chokes ...
Page 342: ...342 EMC filters ...
Page 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Page 349: ...Dimension drawings 349 ...
Page 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Page 351: ...Dimension drawings 351 ...
Page 352: ...Dimension drawings 352 Frame size D ...
Page 354: ...354 Dimension drawings EMC filters JFI 0x ...
Page 356: ...356 Dimension drawings Brake resistors JBR xx ...
Page 358: ...358 Dimension drawings ...