Parameters 285
99.07
MOT NOM POWER
Defines the nominal motor power. Must be equal to
the value on the motor rating plate. If several motors
are connected to the inverter, enter the total power of
the motors. Set also parameter
MOT NOM
COSFII.
Note:
This parameter cannot be changed while the
drive is running.
- /
0.00…
10000.00 kW
Nominal motor power.
- /
100 = 1 kW
99.08
MOT NOM COSFII
Defines the cosphi (not applicable to permanent
magnet motors) for a more accurate motor model.
Not obligatory; if set, should be equal to the value on
the motor rating plate.
Note:
This parameter cannot be changed while the
drive is running.
0.00 /
0.00…1.00
Cosphi (0 = parameter disabled).
- / 100 = 1
99.09
MOT NOM
TORQUE
Defines the nominal motor shaft torque for a more
accurate motor model. Not obligatory.
Note:
This parameter cannot be changed while the
drive is running.
0.000 N•m /
0.000…
2147483.647
N•m
Nominal motor shaft torque.
- / 1000 =
1 N•m
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Summary of Contents for ACL30
Page 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 34: ...34 Operation principle and hardware description ...
Page 42: ...42 Planning the cabinet installation ...
Page 60: ...60 Planning the electrical installation ...
Page 126: ...126 Using the control panel ...
Page 318: ...318 Maintenance ...
Page 334: ...334 The Safe torque off function ...
Page 338: ...338 Mains chokes ...
Page 342: ...342 EMC filters ...
Page 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Page 349: ...Dimension drawings 349 ...
Page 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Page 351: ...Dimension drawings 351 ...
Page 352: ...Dimension drawings 352 Frame size D ...
Page 354: ...354 Dimension drawings EMC filters JFI 0x ...
Page 356: ...356 Dimension drawings Brake resistors JBR xx ...
Page 358: ...358 Dimension drawings ...