Parameters 287
IDrotating
Rotating ID run. The motor must be de-coupled from
the lift system.
3
Autophs turn
Turning autophasing, that determines the start angle
of the motor. Note that other motor model values are
not updated. See also, section
on page
Note
:
• Autophasing can only be selected after the ID run
is performed once. Autophasing is used when an
absolute encoder, a resolver or an encoder with
commutation signals is added/changed to a
permanent magnet motor.
• The motor must be de-coupled from the lift
system.
4
Autophs st1
Standstill autophasing mode 1.
5
Autophs st2
Standstill autophasing mode 2.
6
Autophs rope
Turning autophasing with ropes on. This method can
be used if the lift cabin is allowed to move few tens of
centimeters up.
7
Cur meas cal
Current offset and gain measurement calibration.
The calibration will be performed at the next start.
8
99.11
PHASE INVERSION
Defines the motor rotation direction. The direction
change can function without exchanging the
positions of two motor cable phase conductors at the
drive output terminals or at the motor connection
box.
No /
No
No motor phase inversion.
0
Yes
Motor phases inverted, that is motor rotation
direction is changed.
1
99.12
POS OFFSET SRC
Select the source for the angle offset between the
zero position of the synchronous motor and the zero
position of the position sensor.
Drive mem /
Drive mem
Drive uses the angle offset stored in drive memory
unit.
0
Encoder mem
Drive uses the angle offset stored in encoder
memory.
Note
: This selection is supported with FEN-11
(EnDat and Hiperface).
1
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Summary of Contents for ACL30
Page 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 34: ...34 Operation principle and hardware description ...
Page 42: ...42 Planning the cabinet installation ...
Page 60: ...60 Planning the electrical installation ...
Page 126: ...126 Using the control panel ...
Page 318: ...318 Maintenance ...
Page 334: ...334 The Safe torque off function ...
Page 338: ...338 Mains chokes ...
Page 342: ...342 EMC filters ...
Page 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Page 349: ...Dimension drawings 349 ...
Page 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Page 351: ...Dimension drawings 351 ...
Page 352: ...Dimension drawings 352 Frame size D ...
Page 354: ...354 Dimension drawings EMC filters JFI 0x ...
Page 356: ...356 Dimension drawings Brake resistors JBR xx ...
Page 358: ...358 Dimension drawings ...