288 Parameters
Set zero pos
Sets the zero position of angle offset to the encoder
memory. Parameter
ENC PAR REFRESH
must be selected to activate the writing procedure to
the encoder.
Note
: This selection is supported with FEN-11
(EnDat and Hiperface).
2
99.13
SLIP GAIN
Defines the slip gain which is used to improve the estimated
motor slip. 100% means full slip gain; 0% means no slip
gain. The default value is 100%. Other values can be used if
a static speed error is detected despite of the full slip gain.
Example (with nominal load and nominal slip of 40 rpm): A
1000 rpm constant speed reference is given to the drive.
Despite of the full slip gain (= 100%), a manual tachometer
measurement from the motor axis gives a speed value of
998 rpm.
The static speed error is 1000 rpm - 998 rpm = 2 rpm.
Error can be compensated by increasing slip gain. At 105%
gain value, no static speed error exists (2 rpm / 40 rpm =
5%).
100% /
0…200%
Slip gain.
-
99.14
CTRL UNIT
SUPPLY
Defines the manner in which the drive control unit is
powered.
False /
False
Drive control unit is powered by internal 24 V.
True
Drive control unit is powered by external supply.
99.15
FAN CTRL MODE
Selects the control mode for the drive cooling fan.
Normal /
Normal
The drive cooling fan runs during drive modulation.
0
Advanced
The drive cooling fan is temperature controlled.
1
99.16
PHASE LOSS TEST
Selects the motor phase loss test procedure at the
drive start.
Enable /
Disable
Motor phase loss test disabled.
0
Enable
Motor phase loss test enabled.
1
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Summary of Contents for ACL30
Page 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 34: ...34 Operation principle and hardware description ...
Page 42: ...42 Planning the cabinet installation ...
Page 60: ...60 Planning the electrical installation ...
Page 126: ...126 Using the control panel ...
Page 318: ...318 Maintenance ...
Page 334: ...334 The Safe torque off function ...
Page 338: ...338 Mains chokes ...
Page 342: ...342 EMC filters ...
Page 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Page 349: ...Dimension drawings 349 ...
Page 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Page 351: ...Dimension drawings 351 ...
Page 352: ...Dimension drawings 352 Frame size D ...
Page 354: ...354 Dimension drawings EMC filters JFI 0x ...
Page 356: ...356 Dimension drawings Brake resistors JBR xx ...
Page 358: ...358 Dimension drawings ...