300 Fault tracing
0006
EARTH FAULT
Programmable
fault:
EARTH
FAULT
Drive has detected load
unbalance typically due to
an earth fault in the motor
or motor cable.
Check that there are no power
factor correction capacitors or
surge absorbers in the motor cable.
Check that there is no earth fault in
the motor or motor cables:
measure insulation resistances of
motor and motor cable.
If no earth fault can be detected,
contact your local ABB
representative.
0007
FAN FAULT
Fan is not able to rotate
freely or the fan is
disconnected. Fan
operation is monitored by
measuring the fan current.
Check the fan operation and
connection.
0008
IGBT OVERTEMP
Drive temperature based
on the thermal model has
exceeded the internal fault
limit.
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-
up.
Check motor power against unit
power.
0009
BC WIRING
Brake resistor short circuit
or brake chopper control
fault.
Check brake chopper and brake
resistor connection.
Ensure that the brake resistor is not
damaged.
0010
BC SHORT
CIRCUIT
Short circuit in brake
chopper IGBT.
Ensure that the brake resistor is
connected and not damaged.
0011
BC OVERHEAT
Brake chopper IGBT
temperature has exceeded
the internal fault limit.
Let the chopper cool down.
Check for excessive ambient
temperature.
Check for cooling fan failure.
Check for obstructions in the air
flow.
Check the dimensioning and
cooling of the cabinet.
Check resistor overload protection
function settings, parameters
Check that the braking cycle meets
allowed limits.
Check that the drive supply AC
voltage is not excessive.
Code Fault
Cause
What to do
Summary of Contents for ACL30
Page 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 34: ...34 Operation principle and hardware description ...
Page 42: ...42 Planning the cabinet installation ...
Page 60: ...60 Planning the electrical installation ...
Page 126: ...126 Using the control panel ...
Page 318: ...318 Maintenance ...
Page 334: ...334 The Safe torque off function ...
Page 338: ...338 Mains chokes ...
Page 342: ...342 EMC filters ...
Page 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Page 349: ...Dimension drawings 349 ...
Page 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Page 351: ...Dimension drawings 351 ...
Page 352: ...Dimension drawings 352 Frame size D ...
Page 354: ...354 Dimension drawings EMC filters JFI 0x ...
Page 356: ...356 Dimension drawings Brake resistors JBR xx ...
Page 358: ...358 Dimension drawings ...