308 Fault tracing
0058
FIELDBUS PAR
ERROR
The drive does not have a
functionality requested by
PLC, or the requested
functionality has not been
activated.
Check PLC programming.
Check fieldbus parameter settings.
See parameter group
.
0061
SPEED
FEEDBACK
No speed feedback is
received.
Check the settings of the
parameters in group
.
Check encoder installation. See the
description of fault
(ENCODER1) for more information.
0067
FPGA ERROR1
Drive internal fault
Contact your local ABB
representative.
0068
FPGA ERROR2
Drive internal fault
Contact your local ABB
representative.
0069
ADC ERROR
Drive internal fault
Contact your local ABB
representative.
0077
BRAKE NOT
CLOSED MON2
Programmable
fault:
BRAKE
FAULT FUNC
Mechanical brake control
fault. The fault is activated
if brake monitoring is not
as expected during brake
closing.
Check the mechanical brake
connection.
Check mechanical brake settings,
parameters
To determine whether the problem
is with the monitoring signal or
brake: Check if the brake is closed
or open.
0078
BRAKE NOT
OPEN MON2
Programmable
fault:
BRAKE
FAULT FUNC
Mechanical brake control
fault. The fault is activated
if brake monitoring is not
as expected during brake
opening.
Check the mechanical brake
connection.
Check mechanical brake settings,
parameters
To determine whether the problem
is with the monitoring signal or
brake: Check if the brake is closed
or open.
0201
T2 OVERLOAD
Firmware time level 2
overload
Note:
This fault cannot be
reset.
Contact your local ABB
representative.
0201
T3 OVERLOAD
Firmware time level 3
overload
Note:
This fault cannot be
reset.
Contact your local ABB
representative.
0203
T4 OVERLOAD
Firmware time level 4
overload
Note:
This fault cannot be
reset.
Contact your local ABB
representative.
Code Fault
Cause
What to do
Summary of Contents for ACL30
Page 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 34: ...34 Operation principle and hardware description ...
Page 42: ...42 Planning the cabinet installation ...
Page 60: ...60 Planning the electrical installation ...
Page 126: ...126 Using the control panel ...
Page 318: ...318 Maintenance ...
Page 334: ...334 The Safe torque off function ...
Page 338: ...338 Mains chokes ...
Page 342: ...342 EMC filters ...
Page 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Page 349: ...Dimension drawings 349 ...
Page 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Page 351: ...Dimension drawings 351 ...
Page 352: ...Dimension drawings 352 Frame size D ...
Page 354: ...354 Dimension drawings EMC filters JFI 0x ...
Page 356: ...356 Dimension drawings Brake resistors JBR xx ...
Page 358: ...358 Dimension drawings ...