Technical data 323
Supply cable fuses
Fuses for short circuit protection of the supply cable are listed below. The fuses also
protect the adjoining equipment of the drive in case of a short circuit. Check that the
operating time of the fuse is below 0.5 seconds. The operating time depends on the
supply network impedance and the cross-sectional area and length of the supply
cable. See also chapter
Planning the electrical installation
.
Note:
Fuses with a higher current rating must not be used.
Drive type
ACL30-04...
Input
current
(A)
IEC fuse
UL fuse
Cross-sectional
area of cable
Rated
current
(A)
Volta
ge (V)
Class Rated
current
(A)
Volta
ge (V)
UL
Class
mm
2
AWG
-06A0
7.0*
10
500
gG
10
600
T
1.5 … 4
16…12
-09A0
10.5*
16
500
gG
15
600
T
1.5 … 10 16…8
-013A
15.2*
20
500
gG
20
600
T
1.5 … 10 16…8
-017A
19.8*
25
500
gG
25
600
T
1.5 … 10 16…8
-023A
17.7
25
500
gG
25
600
T
6 ... 35
9…2
-030A
23.0
32
500
gG
35
600
T
6 ... 35
9…2
-050A
41.8
50
500
gG
50
600
T
10 ... 70
6…2/0
-070A
58.4
80
500
gG
80
600
T
10 ... 70
6…2/0
*Without mains choke
PDM-00425726
Summary of Contents for ACL30
Page 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 34: ...34 Operation principle and hardware description ...
Page 42: ...42 Planning the cabinet installation ...
Page 60: ...60 Planning the electrical installation ...
Page 126: ...126 Using the control panel ...
Page 318: ...318 Maintenance ...
Page 334: ...334 The Safe torque off function ...
Page 338: ...338 Mains chokes ...
Page 342: ...342 EMC filters ...
Page 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Page 349: ...Dimension drawings 349 ...
Page 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Page 351: ...Dimension drawings 351 ...
Page 352: ...Dimension drawings 352 Frame size D ...
Page 354: ...354 Dimension drawings EMC filters JFI 0x ...
Page 356: ...356 Dimension drawings Brake resistors JBR xx ...
Page 358: ...358 Dimension drawings ...