Parameters 225
AI2 max tune
Current analogue input AI1 signal value is set as
maximum value for AI1, parameter
AI1 MAX.
The value reverts back to
automatically.
2
AI2 min tune
Current analogue input AI2 signal value is set as
minimum value for AI2, parameter
AI2 MIN.
The value reverts back to
automatically.
3
AI2 max tune
Current analogue input AI2 signal value is set as
maximum value for AI2, parameter
AI2 MAX.
The value reverts back to
automatically.
4
13.12
AI SUPERVISION
Selects how the drive reacts when analogue input
signal limit is reached. The limit is selected by
parameter
AI SUPERVIS ACT
.
No
No action taken.
0
Fault
The drive trips on fault AI SUPERVISION.
1
Spd ref safe
The drive generates alarm AI SUPERVISION and
sets the speed.
WARNING!
In case of a communication
break, make sure that it is safe to continue
operation.
2
Last speed
The drive generates alarm AI SUPERVISION and
freezes the speed to the level the drive was
operating at. The speed is determined by the
average speed over the previous 10 seconds.
WARNING!
In case of a communication
break, make sure that it is safe to continue
operation.
3
13.13
AI SUPERVIS ACT
Selects the analogue input signal supervision limit.
0b0000 /
Example: If the parameter value is set to 0010 (bin),
bit 1 AI1>max is selected.
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Bit
Name
Supervision selected by parameter
AI
SUPERVISION is activated if
0
AI1<min
AI1 signal value falls below the value defined by equation:
par.
AI1 MIN - 0.5 mA or V
1
AI1>max
AI1 signal value exceeds the value defined by equation: par.
AI1 MAX + 0.5 mA or V
2
AI2<min
AI2 signal value falls below the value defined by equation:
par.
AI2 MIN - 0.5 mA or V
3
AI2>min
AI1 signal value exceeds the value defined by equation: par.
AI2 MAX + 0.5 mA or V
Summary of Contents for ACL30
Page 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 34: ...34 Operation principle and hardware description ...
Page 42: ...42 Planning the cabinet installation ...
Page 60: ...60 Planning the electrical installation ...
Page 126: ...126 Using the control panel ...
Page 318: ...318 Maintenance ...
Page 334: ...334 The Safe torque off function ...
Page 338: ...338 Mains chokes ...
Page 342: ...342 EMC filters ...
Page 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Page 349: ...Dimension drawings 349 ...
Page 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Page 351: ...Dimension drawings 351 ...
Page 352: ...Dimension drawings 352 Frame size D ...
Page 354: ...354 Dimension drawings EMC filters JFI 0x ...
Page 356: ...356 Dimension drawings Brake resistors JBR xx ...
Page 358: ...358 Dimension drawings ...