244 Parameters
> 30 min stby
Torque proving is enabled after 30 minutes of
standby.
2
> 1 hr stby
Torque proving is enabled after 1 hour of standby.
3
> 90 min stby
Torque proving is enabled after 90 minutes of
standby.
4
> 2 hr stby
Torque proving is enabled after 2 hours of standby.
5
35.83
TRQ PROVING
REF
Defines the torque proving reference. The Torque
proving function compares the calculated actual
torque of the drive with this reference value.
30.0 % /
0.0...100.0 %
Torque proving reference in percentage of the motor
nominal torque.
10 = 1 % / -
35.84
TRQ PROV FLT
DLY
Defines the time delay for generating fault TORQUE
PROVE. The drive trips on fault TORQUE PROVE if
torque proving is not succeeded by the end of this
period.
1.0 s /
0.0...10.0 s
Time delay for generating fault TORQUE PROVE.
10 = 1 s
35.85
SLIP SPEED LIM
Defines the speed limit for the brake slip during
torque proving.
The drive trips on fault BRAKE SLIP if the actual lift
speed exceeds this limit during torque proving and
stays there for a longer period than defined with
parameter
SLIP FAULT DELAY.
0.05 m/s /
0.00...5.00 m/s
Brake slip speed limit in m/s,
100 = 1 m/s
35.86
SLIP FAULT DELAY
Defines the time delay for generating fault BRAKE
SLIP.
0.5 s /
0.0...10.0 s
Time delay for generating fault BRAKE SLIP,
10 = 1 s/ -
40
40 MOTOR
CONTROL
Settings for motor control.
40.80
SF REF
Defines the switching frequency of the drive.
8 /
4
4 kHz
1
5
5 kHz
2
8
8 kHz
3
12
12 kHz
4
40.81
TORQ BOOST
HYST
Defines the hysteresis for Torque boost function.
When drive is not able to produce requested current,
the switching frequency reduces automatically.
20 % /
0...50 %
Torque boost hysteresis
1 = 1
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Summary of Contents for ACL30
Page 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 34: ...34 Operation principle and hardware description ...
Page 42: ...42 Planning the cabinet installation ...
Page 60: ...60 Planning the electrical installation ...
Page 126: ...126 Using the control panel ...
Page 318: ...318 Maintenance ...
Page 334: ...334 The Safe torque off function ...
Page 338: ...338 Mains chokes ...
Page 342: ...342 EMC filters ...
Page 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Page 349: ...Dimension drawings 349 ...
Page 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Page 351: ...Dimension drawings 351 ...
Page 352: ...Dimension drawings 352 Frame size D ...
Page 354: ...354 Dimension drawings EMC filters JFI 0x ...
Page 356: ...356 Dimension drawings Brake resistors JBR xx ...
Page 358: ...358 Dimension drawings ...