244 Parameters
Displays raw (unmodified) reference REF1 sent by the master
(PLC) to fieldbus adapter A if debugging is enabled by
parameter
This parameter is read-only.
-
-2147483648…
2147483647
Raw REF1 sent by master to fieldbus adapter A.
-
Displays raw (unmodified) reference REF2 sent by the master
(PLC) to fieldbus adapter A if debugging is enabled by
parameter
This parameter is read-only.
-
-2147483648…
2147483647
Raw REF2 sent by master to fieldbus adapter A.
-
Displays the raw (unmodified) status word sent by fieldbus
adapter A to the master (PLC) if debugging is enabled by
parameter
This parameter is read-only.
-
00000000h…
FFFFFFFFh
Status word sent by fieldbus adapter A to master.
-
Displays raw (unmodified) actual value ACT1 sent by fieldbus
adapter A to the master (PLC) if debugging is enabled by
parameter
This parameter is read-only.
-
-2147483648…
2147483647
Raw ACT1 sent by fieldbus adapter A to master.
-
Displays raw (unmodified) actual value ACT2 sent by fieldbus
adapter A to the master (PLC) if debugging is enabled by
parameter
This parameter is read-only.
-
-2147483648…
2147483647
Raw ACT2 sent by fieldbus adapter A to master.
-
51
Fieldbus adapter A configuration.
Displays the type of the connected fieldbus adapter module.
0
= None. Module is not found or is not properly connected, or
1
= PROFIBUS-DP
32
= CANopen
37
= DeviceNet
128
= Ethernet
132
= PROFInet IO
135
= EtherCAT
136
= ETH Pwrlink
485
= RS-485 comm
101
= ControlNet
2222 =
Ethernet/IP
502 =
Modbus/TCP
This parameter is read-only.
-
No.
Name/Value
Description
Def/FbEq16
Summary of Contents for ACQ580
Page 1: ...ABB drives for water Firmware manual ACQ580 pump control program ...
Page 4: ... 2017 ABB Oy All Rights Reserved 3AXD50000035867 Rev C EN EFFECTIVE 2017 06 21 ...
Page 30: ...26 Start up control with I O and ID run ...
Page 40: ...36 Default configuration ...
Page 304: ...300 Parameters ...
Page 340: ...336 Additional parameter data ...