ACQ800-37 Hardware Manual
53
Planning the electrical installation
Planning the electrical installation
What this chapter contains
This chapter contains the instructions that you must follow when selecting the motor,
the cables, the protections, the cable routing and the way of operation for the drive
system.
Note:
The installation must always be designed and made according to applicable
local laws and regulations. ABB does not assume any liability whatsoever for any
installation which breaches the local laws and/or other regulations. Furthermore, if
the recommendations given by ABB are not followed, the drive may experience
problems that the warranty does not cover.
Motor selection and compatibility
1. Select the motor according to the rating tables in chapter
. Use
DriveSize PC tool if the default load cycles are not applicable.
2. Check that the motor ratings lie within the allowed ranges of the drive control
program:
•motor nominal voltage is 1/2 to 2 ·
U
N
of the drive
•motor nominal current is 1/6 to 2 ·
I
2hd
of the drive in DTC control and
0 to 2 ·
I
2hd
in scalar control. The control mode is selected by a drive
parameter.
3. Check that the motor voltage rating meets the application requirements:
See notes 6 and 7 below the
If the drive is equipped with …
… and …
… then the motor voltage
rating should be …
diode supply
(ACQ800-U1)
no resistor braking is used
U
N
frequent or long-term brake cycles
are used
U
ACeq1
IGBT supply
(ACQ800-31, ACQ800-37)
DC link voltage is not increased from
nominal (through parameter settings)
U
N
DC link voltage is increased from
nominal (through parameter settings)
U
ACeq2
U
N
= Rated input voltage of drive
U
ACeq1
=
U
DC
/ 1.35
U
ACeq2
=
U
DC
/ 1.41
U
ACeq
= Equivalent AC power source voltage of drive in V AC
U
DC
= Maximum DC link voltage of drive in V DC. For resistor braking,
U
DC
= 1.21 × nominal DC link
voltage. For units with IGBT supply: see the parameter value.
Note:
Nominal DC link voltage is
U
N
× 1.35 or
U
N
× 1.41 in V DC.
Summary of Contents for ACQ800 Series
Page 1: ...Hardware Manual ACQ800 37 Drives 55 to 450 kW 75 to 550 hp ACQ800 ...
Page 4: ......
Page 12: ...12 ACQ800 37 Hardware Manual Safety instructions ...
Page 24: ...24 ACQ800 37 Hardware Manual About this manual ...
Page 52: ...52 ACQ800 37 Hardware Manual Mechanical installation ...
Page 78: ...78 ACQ800 37 Hardware Manual Electrical installation ...
Page 84: ...84 ACQ800 37 Hardware Manual Motor control and I O board RMIO ...
Page 92: ...92 ACQ800 37 Hardware Manual Installation checklist and start up ...
Page 106: ...106 ACQ800 37 Hardware Manual Maintenance 3 4 5 6 8 7b 7a ...
Page 107: ...ACQ800 37 Hardware Manual 107 Maintenance 9 10 11 View from back ...
Page 123: ...ACQ800 37 Hardware Manual 123 Technical data Declaration of Conformity ...
Page 124: ...124 ACQ800 37 Hardware Manual Technical data ...
Page 128: ...128 ACQ800 37 Hardware Manual Dimensions Frame R6 ...
Page 129: ...ACQ800 37 Hardware Manual 129 Dimensions Frame R6 continued ...
Page 130: ...130 ACQ800 37 Hardware Manual Dimensions Frame R7i ...
Page 131: ...ACQ800 37 Hardware Manual 131 Dimensions Frame R7i continued ...
Page 132: ...132 ACQ800 37 Hardware Manual Dimensions Frame R7i continued ...
Page 133: ...ACQ800 37 Hardware Manual 133 Dimensions Frame R7i continued ...
Page 134: ...134 ACQ800 37 Hardware Manual Dimensions Frame R8i ...
Page 135: ...ACQ800 37 Hardware Manual 135 Dimensions Frame R8i continued ...
Page 136: ...136 ACQ800 37 Hardware Manual Dimensions Frame R8i continued ...
Page 137: ...ACQ800 37 Hardware Manual 137 Dimensions Frame R8i continued ...