Figure 28 Operation of the electromechanical brake control.
Note!
Described functionality is valid from ACS 160 SW version 1.0.0.F.
Start frequency (internal parameter)
Brake Released (open)
Brake On
(closed)
brake delay
5403 MBRK FREQ
LVL
5401 MBRK OPEN DLY
Internal delay
Start/Stop:
F
out
:
Relay output:
Mechanical
brake:
Summary of Contents for ACS 160