104 Control panels
How to view information about the backup
Step Action
Display
1.
Go to the Main menu by pressing
if you are in the
Output mode, otherwise by pressing repeatedly
until
you get to the Main menu.
2.
Go to the Par backup mode by selecting PAR BACKUP
on the menu with keys
and
, and pressing
.
3.
Select BACKUP INFO on the Par backup menu with keys
and
, and press
. The display shows the
following information about the drive where the backup
was made:
DRIVE TYPE:
type of the drive
: rating of the drive in format XXXYZ,
where
XXX: Nominal current rating. If
present, an “A” indicates a decimal
point, eg, 9A7 means 9.7 A.
Y: 2
=
200 V
4 = 400 V
Z:
i = European loading package
n = US loading package
firmware version of the drive.
You can scroll the information with keys
and
.
4.
Press
to return to the Par backup menu.
MENU
EXIT
PARAMETERS
ASSISTANTS
CHANGED PAR
EXIT
ENTER
00:00
LOC
MAIN MENU
1
ENTER
UPLOAD TO PANEL
BACKUP INFO
DOWNLOAD FULL SET
DOWNLOAD APPLICATION
DOWNLOAD USER SET1
EXIT
SEL
00:00
LOC
PAR BACKUP
1
SEL
DRIVE TYPE
ACS355
9A74i
EXIT
00:00
LOC
BACKUP INFO
ACS355
9A74i
241A hex
EXIT
00:00
LOC
BACKUP INFO
EXIT
UPLOAD TO PANEL
BACKUP INFO
DOWNLOAD FULL SET
DOWNLOAD APPLICATION
DOWNLOAD USER SET1
EXIT
SEL
00:00
LOC
PAR BACKUP
1
Summary of Contents for ACS355 series
Page 1: ...ABB machinery drives User s manual ACS355 drives ...
Page 4: ......
Page 16: ...16 ...
Page 32: ...32 Operation principle and hardware description ...
Page 58: ...58 Electrical installation ...
Page 74: ...74 Start up control with I O and ID run ...
Page 106: ...106 Control panels ...
Page 120: ...120 Application macros ...
Page 178: ...178 Program features ...
Page 338: ...338 Fieldbus control with embedded fieldbus ...
Page 368: ...368 Fault tracing ...
Page 404: ...404 Dimension drawings ...
Page 410: ...410 Appendix Resistor braking ...
Page 434: ...434 Appendix Permanent magnet synchronous motors PMSMs ...