Actual signals and parameters 217
1812 MAXIMUM FO Defines the maximum value for frequency output FO.
1000 Hz
10…16000 Hz
Maximum frequency. See parameter
.
1 = 1 Hz
1813 FILTER FO
Defines the filter time constant for frequency output FO, ie,
the time within which 63% of a step change is reached.
0.1 s
0.0…10.0 s
Filter time constant
1 = 0.1 s
19 TIMER &
COUNTER
Timer and counter for start and stop control
1901 TIMER DELAY Defines the time delay for the timer.
10.00 s
0.01…120.00 s Delay time
1 = 0.01 s
1902 TIMER START Selects the source for the timer start signal.
DI1(INV)
Timer start through inverted digital input DI1. Timer start on
the falling edge of digital input DI1.
Note:
Timer start is not possible when reset is active
-1
DI2(INV)
See selection
.
-2
DI3(INV)
See selection
.
-3
DI4(INV)
See selection
.
-4
DI5(INV)
See selection
.
-5
NOT SEL
No start signal
0
DI1
Timer start through digital input DI1. Timer start on the rising
edge of digital input DI1.
Note:
Timer start is not possible when reset is active
1
DI2
See selection
.
2
DI3
See selection
.
3
DI4
See selection
.
4
DI5
See selection
.
5
START
External start signal, eg, start signal through fieldbus
6
1903 TIMER RESET Selects the source for the timer reset signal.
DI1(INV)
Timer reset through inverted digital input DI1. 0 = active, 1 =
inactive.
-1
DI2(INV)
See selection
.
-2
DI3(INV)
See selection
.
-3
DI4(INV)
See selection
.
-4
DI5(INV)
See selection
.
-5
NOT SEL
No reset signal
0
DI1
Timer reset through digital input DI1. 1 = active, 0 = inactive. 1
DI2
See selection
.
2
All parameters
No.
Name/Value
Description
Def/FbEq
Summary of Contents for ACS355 series
Page 1: ...ABB machinery drives User s manual ACS355 drives ...
Page 4: ......
Page 16: ...16 ...
Page 32: ...32 Operation principle and hardware description ...
Page 58: ...58 Electrical installation ...
Page 74: ...74 Start up control with I O and ID run ...
Page 106: ...106 Control panels ...
Page 120: ...120 Application macros ...
Page 178: ...178 Program features ...
Page 338: ...338 Fieldbus control with embedded fieldbus ...
Page 368: ...368 Fault tracing ...
Page 404: ...404 Dimension drawings ...
Page 410: ...410 Appendix Resistor braking ...
Page 434: ...434 Appendix Permanent magnet synchronous motors PMSMs ...